Skip to content

Solutions

i-CTS is a complete, single-vendor solution for high-speed cable production testing: a self-developed vector network analyzer, the MSW matrix switch and i-CTS test software. Frequency options of 26.5 / 40 / 67 GHz and 64 to 384 ports scale to any production line.

One system, three self-developed pillars

VNA mainframe

Self-developed vector network analyzer up to 67 GHz with dynamic range up to 135 dB — overall performance on par with the industry benchmark.

MSW matrix switch

Scales the system from 64 to 384 test ports so a single station covers complete multi-pair cable assemblies without re-cabling.

i-CTS test software

Full support for PCIe 4.0/5.0/6.0, IEEE 802.3cd/ck/dj, CEI 4.0/5.0/5.1 and SAS algorithms, with self-developed IFD automatic de-embedding matching benchmark AFR/ISD accuracy.

Measured efficiency on customer production lines

Customer applicationi-CTSBenchmark systemCapacity gain
A — 16-pair cable, full S-parameter test19 s38 s+100%
D — 12-pair cable, full S-parameter test17 s34 s+100%
E — 16-pair cable, 4000 points32 s45 s+41%
H — 8-pair cable, full S-parameter test17 s66 s+288%
F — 16 cables per cycle4 s7 s+75%
M — crosstalk test added198 s290 s+46%
N — crosstalk test added165 s383 s+132%

The industry’s only 112G → 224G upgrade path

Protect your investment: the VNA4435 mainframe returns to the factory for a hardware upgrade to 67 GHz in about one month — and ships back with a new 3-year warranty. No other cable test platform offers this.

Proven consistency and stability

VNA4435 vs E5080B

Insertion loss difference < 0.02 dB, phase < 0.2°, return loss −45 dB across the full range.

i-CTS vs PNA (N5224B)

On x8 DAC cable: insertion loss difference < 0.1 dB, impedance < 1 Ω, crosstalk envelope < 2 dB.

14-day stability run

10 MHz–40 GHz, 4000 points: SDD21 variation only 0.13–0.15 dB, NEXT 0.99 dB, FEXT 0.91 dB, TDD11 0.01 Ω.

Simplified calibration

Two-port electronic calibration kits complete a full 64-port calibration in just 36 steps — minutes instead of hours, with no manual reconnection errors.

Customer case: global top-tier high-speed cable manufacturer

Testing PCIe 6.0 x8 16-pair cable assemblies (SlimSAS and server internal cables) at 10 MHz–26.5 GHz, 100 kHz IFBW, 2000 points: 128 tests (16 differential pairs + 7 crosstalk) completed in about 60 seconds — more than 15% faster than the incumbent system, with result deviation under 5%. The customer purchased more than 10 i-CTS systems.

View i-CTS specifications and downloads Talk to an engineer